博文

What is the check cycle for SF6 gas density monitor?

图片
  According to what basis? Is there a national standard?   Density relay detection practice   1, detection cycle and testing requirements   According to the provisions of the national standard and industry standards, SF6 electrical equipment testing cycle and requirements are as follows:   1) The new SF6 electrical equipment is required to carry out gas density relay detection.   2) on the operation of the sf6 gas density monitor detection cycle is defined as: handover, the operation of 1 to 3 years, after overhaul, if necessary.     3) gas density relay action value, should meet the technical requirements of the product or according to the manufacturer. The error of the indication value of the pressure gauge and its variation shall be within the allowable error range of the corresponding grade of the product.   There are a lot of foreign products related to the contents of this manual, as every 5 to 10 years of maintenance...

Introduction of density relay calibrator

图片
Frequency conversion series resonant voltage test device found that this year, Hubei Electric Power Company in accordance with the State Grid Corporation to promote the integration of information and communication work in general, in accordance with the requirements of the integrated operation system, Wuhan Hengda Electric Co., Ltd. SF6 density relay calibrator The establishment of information and communication dispatching center, the integration of information and communication scheduling resources, relying on the relevant technical support system, the development of integrated monitoring platform, information and communication dispatchers on duty, to achieve information communication operation monitoring, fault handling, scheduling command " "Unified monitoring information communication sf6 gas density monitor system and equipment operation status and key indicators, unified scheduling information and communication system resources and operation mode, unifi...

SF6 gas density relay on-site inspection of the relevant issues

图片
SF6 gas has been widely used in high pressure, ultrahigh voltage electrical equipment as insulation and arcogenic medium because of its excellent insulation, arc suppression characteristics and stable chemical properties. While the electrical equipment of the dielectric strength and arc suppression capacity depends on the density of SF6 gas. SF6 gas density will bring two aspects of the harm, first, resulting in lower voltage strength of electrical equipment, and second, led to the circuit breaker breaking capacity decline. In addition, the SF6 density relay reduction is usually caused by leakage, and leakage is often accompanied by the atmosphere of water into the equipment penetration, resulting in SF6 gas water content increased, resulting in electrical equipment, insulation performance further decreased.   Therefore, in order to ensure the safe and reliable operation of electrical equipment, it is necessary to monitor the density of SF6 gas.  sf6 gas dens...

Why should the power sector carry out the SF6 gas density relay check?

图片
SF6 gas density relay calibration is the power sector must do the test, which appeared specifically for the SF6 gas density relay calibration instrument-SF6 gas density relay calibrator. Why should the power sector carry out the SF6 gas density relay check? SF6 switch is widely used in power systems, high voltage electrical appliances, SF6 switch reliable operation has become one of the most concerned about the electricity sector. SF6 gas density relay is used to monitor the SF6 switch in the body sf6 gas density monitor changes in the important components, its performance directly affects the SF6 switch running safe. SF6 gas density relay operating on the site due to lack of action, after a period of time often occurs when the action is not flexible, poor contact and other phenomena, and some will appear density relay temperature compensation performance deterioration, when the ambient temperature mutation often lead to SF6 density Relay malfunction. Therefore, DL / T596-1996 ...

Working principles of SF6 gas density table

图片
  1. When the density meter is not installed, if the ambient temperature is 20 ℃, the pointer 2 points to 0MP, but if the ambient temperature is not 20 ℃, because the double-layer metal belt 3 is in accordance with the ambient temperature and 20 ℃ difference to compensate So that when the ambient temperature is higher than 20 ° C, the double-layer metal strip 3 is elongated and its lower end is displaced in the direction of 5, causing the gear mechanism and the pointer 2 to move in the direction in which the density or pressure indication value decreases, The reading of the pointer 2 is greater than 0MP; otherwise, when the ambient temperature is below 20 ° C, the gear mechanism and the pointer 2 will move in the direction of increasing the density or pressure indication value. 2. When the SF6 gas is charged to the circuit breaker , the end of the elastic metal pipe 1 is displaced in the direction of 4 as the gas pressure is gradually increased, and the double-layer metal strip...

SF6 density relay

图片

The introduction of SF6 Gas Density Relay

SF6 density relay Gas pressure meters for SF6-gases are pressure gauges with electrical accessories, mainly for switching equipment in the energy industry. It sets the pressure measurement and limit switches in one device. The effect of ambient temperature is adjusted by a special compensation system. The densitometer is calibrated according to the fill pressure, calibration pressure, switch point and ambient temperature in the case of use. The instrument can provide indoor models, can also be used for outdoor inflatable or filling type. sf6 gas density monitor , SF6 gas density monitor with SF6 gas density relay, SF6 gas density monitor with SF6 gas density relay, SF6 gas density relay, SF6 gas density monitor with SF6 gas density relay, With temperature compensation SF6 gas density relay, without temperature compensation SF6 gas density controller, high precision SF6 gas density monitor and so on.